Workbook of Diagnostics for Cardiac Implantable Devices [E-Book]
Publisher: Minneapolis : Cardiotext Publishing, [2020]Description: 1 online resourceContent type:- text
- computer
- online resource
- 9781942909453
- 1942909454
Item type | Home library | Class number | URL | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|
Electronic book | Stenhouse Library | Link to resource | Available |
Intro -- Cover -- Online Access -- Title Page -- Copyright -- Contents -- Contributors -- Preface -- Abbreviations -- Case 1 Variation in Paced QRS Morphology -- Case 2 Ventricular Undersensing in a Dual-Chamber Pacemaker -- Case 3 Atrial Pacing with a Competing Junctional Rhythm -- Case 4 Loss of AV Synchrony -- Case 5 Postventricular Atrial Refractory Period (PVARP) Function -- Case 6 Atrial Loss of Capture -- Case 7 Loss of Capture and Pseudofusion -- Case 8 Loss of RV and LV Capture -- Case 9 Atrial Undersensing -- Case 10 Functional Atrial Undersensing
Case 11 Undersensing of Atrial Arrhythmia -- Case 12 Ventricular Safety Pacing -- Case 13 DDI Pacing Mode -- Case 14 Functional Ventricular Undersensing -- Case 15 Atrial Sensed Events in Refractory Period -- Case 16 Pseudo-Wenckebach Upper Rate Behavior -- Case 17 Pseudo-Wenckebach Upper Rate Behavior -- Case 18 Pseudo-Wenckebach Upper Rate Behavior -- Case 19 His Pacing Threshold at Implant -- Case 20 Crosstalk Oversensing on Ventricular Channelwith His Pace/Sense Lead in RV Port -- Case 21 Pseudo Undersensing in Leadless Pacemaker -- Case 22 Remote Alert Follow-Up
Case 23 Promoting Intrinsic Ventricular Conduction -- Case 24 Atrial Preference Pacing -- Case 25 Rate Drop Response -- Case 26 Rate Smoothing -- Case 27 Atrial Flutter Response -- Chapter 28 Atrial Tachyarrhythmia with Atrial Intervention Pacing -- Chapter 29 Mode Switch Termination with Failure to Establish AV Synchrony -- Chapter 30 Inappropriate Mode Switch -- Chapter 31 Loss of AV Synchrony Due to Inappropriate Mode Switch -- Chapter 32 Auto-PVARP and Inappropriate Mode Switch -- Chapter 33 Pacemaker-Mediated Tachycardia -- Chapter 34 Pacemaker-Mediated Tachycardia Intervention
Chapter 35 Pacemaker-Mediated Tachycardia in CRT-P -- Chapter 36 Respiratory Trends and Atrial Oversensing -- Chapter 37 Signal Artifact Monitor -- Chapter 38 Ventricular Noise Reversion -- Chapter 39 Ventricular Oversensing with RV Lead Failure -- Chapter 40 Atrial Oversensing -- Chapter 41 Noise Oversensing -- Chapter 42 Electromagnetic Interference in ICD -- Chapter 43 RV Lead Failure -- Chapter 44 RV Lead Fracture -- Chapter 45 Atrial Oversensing with Inappropriate Mode Switchand Arrhythmia Induction -- Chapter 46 Short-Long-Short-Induced Ventricular Tachycardia
Chapter 47 Managed Ventricular Pacing Modeand Ventricular Arrhythmias -- Chapter 48 Ventricular Pacing in the Vulnerable Period Due to Blanking and Associated Arrhythmia -- Chapter 49 Ventricular Pacing in the Vulnerable Period During Atrial Flutter -- Chapter 50 T-Wave Oversensing -- Chapter 51 RV Lead Integrity Warning and T-Wave Oversensing Discrimination -- Chapter 52 Subcutaneous ICD Oversensing -- Chapter 53 Mode Switch During VT Detection -- Chapter 54 Single-Chamber ICD with Atrial Sensing -- Chapter 55 Medtronic Detection Zones with Fast VT via VT versus Fast VT via VF
Perfect for exam prep, training across CIED devices, and as a reference to keep on hand in the lab. Real-world examples of managing a specific device-related issue. Includes straightforward clinical management issues to more complex issues that may be related to a specific device algorithm.
WorldCat record variable field(s) change: 050
There are no comments on this title.